T1870 000:029.194 SEGGER J-Link V7.80c Log File
|
T1870 000:029.311 DLL Compiled: Sep 27 2022 16:01:16
|
T1870 000:029.335 Logging started @ 2024-07-23 08:39
|
T1870 000:029.343 - 29.347ms
|
T1870 000:029.354 JLINK_SetWarnOutHandler(...)
|
T1870 000:029.364 - 0.013ms
|
T1870 000:029.373 JLINK_OpenEx(...)
|
T1870 000:033.054 Firmware: J-Link ARM-OB STM32 compiled Aug 22 2012 19:52:04
|
T1870 000:033.499 Firmware: J-Link ARM-OB STM32 compiled Aug 22 2012 19:52:04
|
T1870 000:036.511 Hardware: V7.00
|
T1870 000:036.530 S/N: 20090928
|
T1870 000:036.541 OEM: SEGGER
|
T1870 000:036.552 Feature(s): RDI,FlashDL,FlashBP,JFlash,GDB
|
T1870 000:038.068 TELNET listener socket opened on port 19021
|
T1870 000:038.282 WEBSRV WEBSRV_Init(): Starting webserver thread(s)
|
T1870 000:038.338 WEBSRV Failed to put socket into listener state (port 19080)
|
T1870 000:038.399 WEBSRV Webserver running on local port 19081
|
T1870 000:045.411 - 16.047ms returns "O.K."
|
T1870 000:045.441 JLINK_GetEmuCaps()
|
T1870 000:045.453 - 0.016ms returns 0x88EA5833
|
T1870 000:045.468 JLINK_TIF_GetAvailable(...)
|
T1870 000:045.861 - 0.400ms
|
T1870 000:045.878 JLINK_SetErrorOutHandler(...)
|
T1870 000:045.890 - 0.017ms
|
T1870 000:045.914 JLINK_ExecCommand("ProjectFile = "C:\git\XRange_Tag -Ãâ²¼Ïß\MDK-ARM\JLinkSettings.ini"", ...).
|
T1870 000:053.544 Ref file found at: C:\Keil_v5\ARM\Segger\JLinkDevices.ref
|
T1870 000:053.710 REF file references invalid XML file: C:\Program Files (x86)\SEGGER\JLink\JLinkDevices.xml
|
T1870 000:054.084 - 8.177ms returns 0x00
|
T1870 000:057.156 JLINK_ExecCommand("Device = STM32L051C8Tx", ...).
|
T1870 000:059.883 Device "STM32L051C8" selected.
|
T1870 000:060.189 - 3.023ms returns 0x00
|
T1870 000:060.203 JLINK_ExecCommand("DisableConnectionTimeout", ...).
|
T1870 000:060.214 - 0.005ms returns 0x01
|
T1870 000:060.223 JLINK_GetHardwareVersion()
|
T1870 000:060.230 - 0.011ms returns 70000
|
T1870 000:060.239 JLINK_GetDLLVersion()
|
T1870 000:060.246 - 0.010ms returns 78003
|
T1870 000:060.254 JLINK_GetOEMString(...)
|
T1870 000:060.265 JLINK_GetFirmwareString(...)
|
T1870 000:060.272 - 0.011ms
|
T1870 000:069.973 JLINK_GetDLLVersion()
|
T1870 000:069.997 - 0.027ms returns 78003
|
T1870 000:070.006 JLINK_GetCompileDateTime()
|
T1870 000:070.014 - 0.010ms
|
T1870 000:072.525 JLINK_GetFirmwareString(...)
|
T1870 000:072.539 - 0.017ms
|
T1870 000:075.129 JLINK_GetHardwareVersion()
|
T1870 000:075.143 - 0.018ms returns 70000
|
T1870 000:077.681 JLINK_GetSN()
|
T1870 000:077.695 - 0.017ms returns 20090928
|
T1870 000:080.283 JLINK_GetOEMString(...)
|
T1870 000:086.017 JLINK_TIF_Select(JLINKARM_TIF_SWD)
|
T1870 000:087.061 - 1.050ms returns 0x00
|
T1870 000:087.075 JLINK_HasError()
|
T1870 000:087.088 JLINK_SetSpeed(5000)
|
T1870 000:087.423 - 0.340ms
|
T1870 000:087.435 JLINK_GetId()
|
T1870 000:090.780 InitTarget() start
|
T1870 000:090.799 J-Link Script File: Executing InitTarget()
|
T1870 000:105.574 Can not attach to CPU. Trying connect under reset.
|
T1870 000:170.974 Connecting to CPU via connect under reset failed.
|
T1870 000:225.367 InitTarget() end
|
T1870 000:227.861 Connect failed. Resetting via Reset pin and trying again.
|
T1870 000:293.729 InitTarget() start
|
T1870 000:293.756 J-Link Script File: Executing InitTarget()
|
T1870 000:307.785 Can not attach to CPU. Trying connect under reset.
|
T1870 000:373.068 Connecting to CPU via connect under reset failed.
|
T1870 000:427.028 InitTarget() end
|
T1870 000:427.061 - 339.630ms returns 0x00000000
|
T1870 001:283.526 JLINK_Close()
|
T1870 001:288.113 - 4.608ms
|
T1870 001:288.140
|
T1870 001:288.148 Closed
|